Innova Service has been repairing electronics in Baku since 2008. We repair UPS units (uninterruptible power supplies): offline and line-interactive models for home and office, online (double-conversion) UPS units for servers and equipment, and high-power systems with external battery packs. We work with APC, Eaton, PowerCom, CyberPower, Ippon, Delta, Legrand, Vertiv, Socomec, Tripp Lite, Tescom, Tunçmatik, Makelsan and other brands; UPS troubleshooting starts with measurements of the battery and the inverter.
Repairs start from 50 AZN. We find the cause first, then quote the exact price; work starts only with your approval, and we give a warranty on the work done.
Faults we repair
| What happens | Likely cause |
| The UPS shuts off as soon as the power goes out | Worn battery, inverter power components — battery replacement |
| “Replace battery”, red indicator, constant beeping | Battery at the end of its life, charging circuit |
| The UPS won't turn on at all | Fully discharged battery, fuse, power board |
| Not charging the battery | Charge controller, its power circuit — inverter and charger repair |
| “Overload”, shuts off under load | Excessive load, weak battery, inverter, sensor |
| Switches to battery too often, clicks | Input voltage sensitivity, AVR relay, mains supply |
| Burning smell, humming, heating up | Inverter transistors, fan, transformer |
The battery is the part of a UPS that wears out first
Home and office UPS units use 12-volt lead-acid (AGM) batteries. They usually last 3–5 years, and less in Baku's hot summers and in rooms that get warm. A worn battery is the most common cause of the “won't turn on”, “shuts off at once” and “keeps beeping” symptoms. We replace the battery, check the charging circuit and calibrate the UPS — calibration and load testing.
How we repair
- Diagnostics. The batteries, charging circuit, inverter, relay, sensors and board are checked, and the error log is read — service diagnostics.
- Price. We tell you in advance, once the faulty part has been found.
- Repair. The battery is replaced, the board is restored at component level, and the UPS is cleaned of dust.
- Testing. The UPS is run under load: switchover to battery, runtime, charging; we give a warranty on the work.
We do not sell spare parts separately — batteries and other parts are replaced only as part of a repair. About the technician's work — UPS repair technician, prices — UPS repair prices. Inverters for solar and off-grid systems — inverter repair.
Repair or a new UPS: which pays off
The part most often replaced in a UPS is the battery, and replacing it usually costs much less than buying a new unit. For online and high-power UPS units and server equipment, a repair almost always pays off: replacing a burnt transistor, capacitor, relay or fan costs only a small fraction of the price of the whole device. If a small home UPS has both a worn battery and a burnt power board, the repair price may come close to that of a new one — we say so plainly after diagnostics, and the decision is yours.
All major UPS brands
We repair the UPS brands most often found in Baku:
- APC — the Back-UPS series for home and office and the Smart-UPS series for offices and servers.
- Eaton — line-interactive and online models, including rack-mount units for server cabinets.
- PowerCom, CyberPower, Ippon — home and office UPS units for computers, routers and point-of-sale equipment.
- Delta, Legrand, Vertiv — online UPS units and systems with external battery packs for servers, network and medical equipment.
If your brand is not on the list, that is not a problem: UPS units are built on similar circuits — a power supply, a charging circuit, an inverter and a control board. When you call, tell us the brand and model, and we will tell you in advance where the fault is likely to be and roughly what the repair costs.
How to look after a UPS
- Temperature. Keep the UPS away from radiators, direct sunlight and closed cabinets: the warmer the room, the faster the battery ages.
- Load. Do not plug a laser printer, a heater or an electric kettle into the UPS — they cause the “Overload” error and overstress the power components.
- Self-test. Every few months, run the UPS self-test function or briefly unplug it from the mains and see how it runs on battery.
- Dust. When the vents and the fan are clogged with dust, the UPS overheats; during a repair we clean the dust out of it.
How to restart a UPS and shut it down properly
- Save any open files on the computer and switch off the devices connected to the UPS.
- Press and hold the UPS button for a few seconds until it beeps or the indicators go out.
- Unplug the UPS from the wall socket; if you will not use it for a long time, the battery can be disconnected too.
- To restart, plug the cable back in, wait a minute or two and press the button. If the error remains, do not keep switching the UPS on — it needs diagnostics.
UPS units and voltage stabilizers
Line-interactive UPS units have AVR (automatic voltage regulation): when the voltage drops or rises slightly, the UPS corrects it without switching to battery, so it works like a small stabilizer. Unlike stand-alone voltage stabilizers, though, its range is narrow: if the mains voltage often goes beyond it, the UPS keeps switching to battery, and the relay and the battery wear out quickly. Adjusting the UPS input sensitivity or adding a separate stabilizer in front of it helps here — at diagnostics we look at the error log and tell you which is needed.
UPS batteries
If a UPS cannot hold the load or beeps when the power goes out, the batteries have most likely worn out. Battery replacement is part of a UPS repair: we match the batteries by capacity and voltage and check the charging circuit at the same time, because a faulty charger quickly ruins new batteries. Every uninterruptible power supply repair starts with measurements, so we tell you in advance whether the batteries need replacing or the board is faulty.
Besides the brands above, we repair UPS units from Socomec, Tripp Lite, Makelsan, Tescom, Tunçmatik, EnEl, ElEn and other manufacturers.
Which countries' UPS units we repair
We do not sell UPS units — our work is repairing and servicing them, so the country of manufacture makes no difference to us: their circuits are similar. Troubleshooting a UPS of any brand starts with measurements.
- USA and Europe. APC and Schneider Electric, Eaton and Powerware, MGE, Vertiv, Legrand, Socomec, Riello, Siel, Masterguard.
- Türkiye. Inform, Tunçmatik, Makelsan, Tescom, Esis Power, Upset.
- Asia and other countries. Delta, CyberPower, PowerCom, Must, Astrid, Gamatronic, Mytec, Mercury, Ceres and other brands.
How to choose a UPS: what to look at
- Type. Standby (offline) for a home computer, line-interactive for an office and mains with voltage swings, online (double conversion) for servers, medical and other sensitive equipment.
- Power with headroom. Add up the wattage of the devices you will connect and add 20–30%: a UPS running at its limit heats up, and its power components fail sooner.
- Output waveform. Pumps, boilers and equipment with motors need a pure sine wave; cheaper models with a stepped (simulated) sine wave suit computers only.
- Run time. It depends on battery capacity. If the load has to be held for a long time, choose a model that takes external battery packs rather than one with a single built-in battery.
- Ease of repair. Standard-size batteries, access to them without taking the case apart, an error log and a widespread brand make servicing and repair easier.
If the computer itself does not start after a power cut, the fault is usually in its power supply or motherboard — computer repair.
Most UPS failures we see start on the power board — what fails there and how it is repaired is explained in our guide to UPS power board faults.
Besides UPS units, our service center repairs computers, monitors and other devices — electronics repair services.